CX-E-60(R)
IEC category C2/D1 compliant
Conforming standards
- IEC 61643-21 compliant
- RoHS compliant
Features
- Analog camera protection
- ITV camera protection
- BNC type connector
- Compatible with Category C2 and Category D1
- Can be mounted on a DIN rail (35mm width)
- Deterioration diagnosis can be performed using the ZPT1 tester
Application
- Monitoring cameras (power superimposition enabled)
- Data transmission devices
specification
| item | condition | performance | remarks |
|---|---|---|---|
| Frequency Band | - | DC ~ 50 MHz | - |
| impedance | - | 50 Ω、75 Ω | - |
| Insertion Loss | DC ~ 50MHz | ≤ 1.0 dB | - |
| Maximum continuous working voltage UC | - | DC 70 V | Between the center conductor and the outer conductor |
| Rated current | - | 1 A | - |
| Breakdown voltage | 1 mA | 90 V or less | Between the center conductor and the outer conductor |
| 100V/s peak hold | 280 V or less | Between each conductor - outer conductor | |
| Voltage protection level | 1.2/50 μs、10 kV | 250 V or less | Between the center conductor and the outer conductor |
| 500 V or less | Conductor-to-ground | ||
| Impulse durability | 8/20 μs | 10 kA, 10 times | Category C2 |
| 10/350 μs | 2 kA, 2 times | Category D1 | |
| Insulation Resistance | DC 100 V | 100 MΩ or more | Conductor-to-ground |
| DC 70 V | 35 MΩ or more | Between the center conductor and the outer conductor | |
| AC durability | 50Hz、1A、1s | 5 times | Conductor-to-ground |
| DC resistance | 1A | 1 Ω ± 20% | Center conductor LINE to EQUIP |
| Overload failure mode | - | Mode 3 | - |
| Deterioration diagnosis | In a dedicated tester | LED on: Normal / LED off: Deterioration (replacement required) | - |
| mass | - | about 110 g | - |
Dimensions (Unit: mm)
Download the document
CX-E-60(R)_Instruction Manual (PDF)