U-10B
keyword | 2 poles with lead wire, DC discharge start voltage 600V |
---|---|
Product Info | Product name: U-10B (UL) Item code: 11008117 |
Mounted between the neutral line and ground of the communication circuit board and power supply circuit of the 2-pole arrester (GDT) communication device, and used to protect the device from induced voltage and TOV (temporary overvoltage) induced in the line to do.
Main applications
- various electronic devices and protection of communication lines
- switch
- PBX
- telephone
- FAX
- AC power
- Inverter
・ Small size and high current resistance
・ Low capacitance
・ Broadband compatible
・ Excellent heat and mechanical shock due to use of ceramic envelope
・ Excellent current resistance and temperature environment characteristics of repeated surge
Dimensions (Unit: mm)
Specification
item | conditions | Performance |
DC discharge start voltage | 100 V / s | 600 V ± 15% |
Impulse discharge start voltage | 100 V / μs | 800 V or less |
Impulse discharge start voltage | 10 kV / μs | 1200 V or less |
Insulation resistance | DC 250 V | 10000 MΩ or more |
Capacitance | 1 MHz | 1.0 pF or less |
DC holdover voltage | Voltage 150 V, current 200 mA | 150 ms or less |
Alternating current | Voltage 100 V, current 80 A, 50 Hz | 1/2 cycle or less |
Impulse life | 10/1000 μs, 500 A | 500 times |
Impulse current capacity | 8/20 μs, 5 kA | 10 times |
Impulse current capacity | 8/20 μs, 10 kA | Once |
AC current tolerance | 10 A, 1 s, 50 Hz | 10 times |
AC current tolerance | 65 A, 9 cycle, 50 Hz | Once |
mass | - | 1.5 g |
Notes on use
When using this product for AC power, be sure to use it together with a varistor.
If the arrester is used alone, a follow current may occur.
We also have AV series (2 poles) and AV3P series (3 poles) with arresters and varistors integrated.