Y05-230B
 
			| keyword | 2 poles Lead wire diameter 0.8mm DC discharge starting voltage 230V | 
|---|---|
| Product Info | Product name: Y05-230B Item code: 11011232 | 
Mounted between the neutral line and ground of the communication circuit board and power supply circuit of the 2-pole arrester (GDT) communication device, and used to protect the device from induced voltage and TOV (temporary overvoltage) induced in the line To do.
Main applications
- various types of electronic equipment and protection of communication lines
- switching equipment
- PBX
- phone
- FAX
・ Small size and large current resistance
・Low capacitance
・ Broadband compatible
・ Excellent heat and mechanical shock due to use of ceramic envelope
・Excellent current resistance and temperature environment characteristics of repeated surge
Dimensions / Recommended land pattern (Unit: mm)
 
					
	
		
									
			
											
	     Specification
| item | conditions | Performance | 
|---|---|---|
| DC discharge start voltage | 100V / s | 230V ± 20% | 
| Impulse discharge start voltage | 1kV / μs | 650V or less | 
| Insulation resistance | DC 100V | 10,000MΩ or more | 
| Capacitance | 1MHz | 1pF or less | 
| DC holdover voltage | DC 52V, ITU-T K. 12 / Test 1 | 150ms or less | 
| Impulse current capacity | 8 / 20μs, 5kA | +5 times, -5 times | 
| Impulse life | 10 / 1000μs, 100A | 300 times | 
| AC current tolerance | 50Hz, 5A, 1s | 10 times | 
| mass | - | 0.7g | 
Notes on use
When using this product for AC power, be sure to use it together with a varistor.
If the arrester is used alone, a follow current may occur.
We also have AV series (2 poles) and AV3P series (3 poles) with arresters and varistors integrated.