LAN-CAT6A-P+II (R)

IEC category C2/D1 compliant

Conforming standards

  • IEC61643-21:2009 / JIS C 5381-21:2014
  • IEC61000-4-5:2005 / JIS C 61000-4-5:2009
  • UL File Number: E140906
  • RoHS compliant

Features

  • Discharge type circuits
  • Gigabit Ethernet 10GBase-T enabled
  • PoE++ (IEEE802.3bt) enabled
  • DIN rail mountable (35mm)
  • Mountable on conductive DIN rail for batch earthing

New !!  Easy checking deterioration 

Application

  • Gigabit Ethernet
  • Network cameras
  • Wireless LAN accress point
  • VoIP enabled telephones and servers
  • Outdoor installed network devices

Characteristics

connector RJ-45 8-pole8-core
Supported Lines

10BASE-T

100BASE-TX

1000BASE-T

2.5GBASE-T

5GBASE-T

10GBASE-T

PoE

PoE+

PoE++

IEEE802.3

IEEE802.3u

IEEE802.3ab

IEEE802.3bz

IEEE802.3bz

IEEE802.3an

IEEE802.3af

IEEE802.3at

IEEE802.3bt

Transmission bandwidth used DC ~ 500 MHz
Transmission Loss

1~100MHz

~250MHz

~500MHz

≤ 1.0 dB

≤ 2.0 dB

4.0 dB or less

Near-end crosstalk attenuation

1~100MHz

~250MHz

~500MHz

>32.3 dB

>35.3 dB

>26.7 dB

Coding error rate 0.01 % or less
Maximum continuous working voltage UC DC 60 V Between each line and ground
Rated current 2,400 mA IEEE802.3af, IEEE802.3at, IEEE802.3bt
Breakdown voltage 100 V/s 160 V ~ 300 V Between each line and ground
Voltage Protection Level Up 1.2/50 μs, 10 kV 500 V or less Between each line and ground
Impulse durability 8/20 μs 5 kA, 10 times Category C2
Impulse durability 10/350 μs 2.5 kA, 2 times Category D1
Maximum discharge current 8/20μs 10kA, 10 times Total value between 8 cores and shield to ground
AC durability 50 Hz, 0.5 A, 1s 5 times
Impulse Reset DC 60 V, 600 mA Within 30 ms Between PoE power supply terminals
Insulation Resistance DC 60 V 1,000 MΩ or more Between each line and ground
Deterioration diagnosis In a dedicated tester LED on: Normal / LED off: Deterioration (replacement required)
mass about 60 g

Dimensions