L-13KIS-1G (Isolation type)

1

Conforming standards

  • IEC 61643-351 compliant
  • RoHS compliant

Features

  • User isolation type circuits
  • Gbase Erthernet 1000BASE-T enabled
  • Earth-free type not requiring earthing construction work or protecting equipment without earthing connectors
  • Impluse withstand voltage 13kV or more

Application

  • Gigabit Ethernet
  • Ordinary households (PCs, network devices)

Characteristics

Item Measurement conditions Performance
Applicable lines IEEE802.3 10BASE-T
IEEE802.3u 100BASE-TX
IEEE802.3ab 1000BASE-T
Transmission loss 3.0dB or less 
AC withstand voltage 4kV or more
Impluse withstand voltage 10/700µs 13kV or more 
1.2/50µs 10kV or more

External view                                           